30 Proven in the Harshest Environments
LEARN MORE
>
TE Connectivity M12
X-Code Field-Installable
Connectors
FIGURE 8: Diiodomethane test results. (TE Connectivity)
DIIODOMETHANE TESTING (FIGURE 8)
Test Conditions and Procedure:
• Samples placed in a chamber:
• 95 percent relative humidity
• 85°C constant temperature
• Total exposure time–500 hours
• Samples tested at 48, 170, 300, and 500 hours
• Samples were compared with standard packaged
sensors (not enhanced for harsh media.
•
Conclusion
TE Connectivity's package design and assembly
procedures provide a sensor with enhanced
resistance to corrosive chemicals and atmospheres.
These design and assembly procedures provide
customers with added confidence that TE
Connectivity sensors will better resist failure
or malfunction in applications in corrosive
environments. ■